VCHRP-TM an universal VFD for AC industrial loads up to 17,500 kVA with 3 kV, 6 kV and 10 kV nominal output voltage. Due to high quality of development and production, VCHRP-TM can operate with the already installed and the new asynchronous or synchro- nous motors.
Ordering products

+7 (8352) 39-57-41, 39-50-88, 39-50-85, 55-52-65

fax +7(8352) 62-38-74

secret@elpri.ru
 " - ".
KRUN KNV 10 switchgear for outdoor usage


Designation

KNV-10 switchgears for outdoor usage are designed as 6 or 10 kV distributing devices and can be used as distributing devices in transformer stations and substations, including complex, modular substations 35/6-10, 110/6-10, 110/35/6-10 kV.

Special features

  •  Division switchgear into panels: relay panel, breaker panel, busbar panel and liner bus panel;
  •  Bottom placement of busbar;
  •  Ground placement of high voltage breaker;
  •  Several types of interlocks for protection from wrong operation during maintenance and repair;
  •  Using vacuum breakers (/L-10, -10, -10, --10, -10, -, -10, 5 Siemens, Evolis Merlin Gerin) as a commutation device;
  •  Building auxiliary connection circuits with electromechanical relays or microprocessor based relaying and automation devices;
  •  Full range of main circuits and auxiliary circuits arrangement to meet customers requests;
  •  Possibility of connection to K-59 by using transitional equipment.

Naming conventions for KRUN KNV-10 switchgear

KRUN KNV 10-<A>-<B>-<C>/<D> <E>

KRUN - switchgear for outdoor usage

- switchgear

N - bottom placement of pullout element

V - distinguishing index of CHEAZ-ELPRY Ltd manufacturer

10 - rated voltage up to 10 kV (6 kV, 10 kV)

<A> - type of build-in breaker: vacuum breaker without letter, SF6-breaker letter G; Low-oil-content breaker letter M)

<B> - Index of main-circuit arrangement

<C> - rated current,

<D> - rated breaking current,


<E> - Climatic versions and area class according to GOST 15150 and GOST 15543.1


Examples:

KRUN KNV-10 switchgear with vacuum breaker, main circuit arrangement N 01, 1600 A rated current, 31,5 kA thermal short-time current rating and Y1 climatic version:

KRUN KNV-10-01-1600/31,5 Y1 BKGI.674551.014 TY.

KRUN KNV-10 switchgear with SF breaker, main circuit arrangement N 05, 1000 A rated current, 20 kA thermal short-time current rating and HL1 climatic version:

KRUN KNV-10-G-01-1000/20 HL1 BKGI.674551.014 TY.

KRUN KNV-10 switchgear with low-oil-content breaker, main circuit arrangement N 08, 630 A rated current, 20 kA thermal short-time current rating and Y1 climatic version:

KRUN KNV-10-M-08-630/20 Y1 BKGI.674551.014 TY.

General quantities and technical data

Name of the parameter value
Rated voltage (line), kV 6; 10
Rated operation voltage (line), kV 7,2; 12
Main circuit rated current, A 630; 1000; 1600
Rated current of busbar, A 1000; 1600; 2000; 2500; 3150
Rated breaking current for installed breaker, kA 12,5; 16; 20; 25; 31,5
Thermal short-time current rating (3 seconds duration), kA 20; 31,5
Short-time withstand current, kA 51; 81
Rated voltage for auxiliary circuits, V
    - for direct current
    - for alternating current
 
110; 220
220
Rated power for auxiliary needs transformers installed in the switchgears, kVA
    - installed in switchgear
    - separate
 
25-40
250

Classification of KNV-10 switchgear

Name of the parameter value
Insulation level according to GOST 1516.3-96 with normal insulation
Insulation type air insulation
combined insulation
Presence of pullout elements in panels with pullout elements
without pullout elements
Type of service double-end service
Type of linear high-voltage feeders cable or bridge
Presence of doors in panels with pullout elements panels without doors
Type of control Local and remote control
Protection class according to GOST 14254-96 Y1 version of KRUN switchgear spraytight IP34;
HL1 version of KRUN switchgear dustproof I54;
When the doors of relay panels are opened and pullout element is in control position - I04;
Basic types of switchgears - with high voltage breaker;
- with plug connection;
- with voltage transformers;
- with power fuses;
- with power transformers;
- with static capacitors;
- with vacuum contactor;
- combined, with voltage transformers and discharger;
Presence of thermal insulation of KRUN switchgear - Y1 version: without thermal insulation
- HL1 version: with thermal insulation
Presence of covered control passage With covered control passage

There are several types of devices used in KNV-10 switchgears:

  •  Vacuum breaker /L-10, -10, -10, --10, -10, -, -10, 5 , Evolis etc.;
  •  Voltage transformers -6(10), -6(10), -08-6(10), 3, 3 etc.;
  •  Current transformers -10, --10, -10 etc.;
  •  Auxiliary transformers , , , etc. with power from 25 up to 250 kVa;
  •  Core balance current transformer , , , , CSH etc.;
  •  Microprocessor based relaying and automation device: , , SEPAM, , SPAC, etc.;

Design

KRUN KNV-10 consists of high voltage panel, installed on rigid metal base and control passage covered with protective metal cover. Main types of switchgears: with high voltage breakers, plug connection, voltage transformer, power fuses, power transformers, static capacitors, vacuum breaker, combined (with voltage transformers and discharger);

To protect maintenance stuff the KRUN KNV-10 switchgear has special features, such as:

  •  Current conducting parts of main circuit which can be under potential after moving pullout element into repair position are closed automatically by specially designed shutters;
  •  there are warning message or warning sign according to GOST 12.4.026;
  •  The shell of pullout element has two constant electrical contacts with switchgear shell in working state, repair state and all position in between.

There are several mechanical and electrical interlocks in switchgear:

  •  an interlock that protect from moving pullout element from working position to control position and from control position to working position if switch installed on pullout element is turned on.
  •  an interlock that prevent turning on the switch installed on pullout element if pullout element is placed between two position;
  •  an interlock that prevent moving pullout element from control position to working position if grounding blades are turned on;
  •  an interlock that prevent from turning on grounding disconnector while pullout element is in working position;
  •  an interlock that prevent moving pullout element while automatic feeder breaker is turned on;
  •  an interlock that prevent from moving pullout element of section breaker in section panel if pullout element of section panel of adjacent switchgear is in working position.

Diagram 1: Design of Y1 climatic version of KRUN KNV-10:
1 switchgear 2 relay panel; 3 pullout element; 4 door of control passage; 5 control passage.

Design of Y1 climatic version of KRUN KNV-10: