VCHRP-TM – an universal VFD for AC industrial loads up to 17,500 kVA with 3 kV, 6 kV and 10 kV nominal output voltage. Due to high quality of development and production, VCHRP-TM can operate with the already installed and the new asynchronous or synchro- nous motors.
Ordering products

+7 (8352) 39-57-41, 39-50-88, 39-50-85, 55-52-65

fax +7(8352) 62-38-74

secret@elpri.ru
ООО "ЧЭАЗ - ЭЛПРИ". Передовые технологии в разработке и производстве энергосберегающего оборудования
Soft start of high electric submersible pumps UPPVE1 PN

Soft start of high electric submersible pumps UPPVE1 PN designed for soft, non-impact starting motors of submersible pumps in manual and automatic modes, with the specific management functions and protection systems.

Soft start of the motor is achieved by forming a preset tempo of the motor voltage buildup from zero to the rated value by following method: thyristor control phases of the soft starter UPPVE1.

The soft starter UPPVE1 PN


The soft starter UPPVE1 PN

The soft starter UPPVE1 PN

The soft starter UPPVE1 PN

 

Main technical characteristics UPPVE1 PN:

Nominal input voltage kV, 50 Hz 1.5 - 4.5
Rated output voltage kV, 50 Hz, 1.5 - 4.5
The range of motor power, kW 250 – 500
Inrush current of the converter, A 630
Limits of inrush current (1 - 4) Irated. motor.
Control circuit power supply, three-phase, 380 V
Synchronization circuit power supply three-phase, 100 V
Adjusted starting time, with 5-60
Thyristors production of "ABB"
Delivery method of control pulses: Optical, complete electrical isolation of control and power modules
Protection class of IP20 (from the front)
Climatic performance UXL4
 

 

Advantages:
  • significantly reduces the starting current of the motor (2 - 4 times);
  • significantly reduce the dynamic loads on the bearings of the motor and the kinematics of the drivers (5 - 7 times);
  • reduces the voltage "drawdown" at start
  • Improve the conditions of operation of electrical equipment (motors, transformers, switchgear, etc.);
  • reduced energy losses in electric at start
  • increases the maximum number of starts and the saving of electric energy through rational use of energy-consuming equipment;
  • increased reliability and service life.
  • provide specific functions of the management, control and protection of submersible pumps.
     

 

The device UPPVE1 PN has the following protection functions:

    • shutdown and prohibition the motor start when overcurrent protection triggered;
    • shutdown and prohibition the motor start when time-current protection triggered;
    • shutdown and prohibition the motor start when protection against the breakdown of the thyristors triggered;
    • shutdown and prohibition the motor start when protection against protracted start triggered;
    • shutdown and prohibition the motor start when protection against phase break on the input of device triggered;
    • shutdown and prohibition the motor start when protection against phase break on the output of device triggered;
    • shutdown and prohibition the motor start when protection against control system failure triggered;
    • shutdown and prohibition the motor start when protection against mains abnormal frequency deviation triggered;
    • protection against inadvertent change settings;
    • shutdown and prohibition the motor start when protection against protection against abnormal power supply deviations triggered;
    • shutdown and prohibition the motor start when protection against the external failure triggered;
    • shutdown and prohibition the motor start when protection against invalid phase sequence triggered;
    • shutdown and prohibition the motor start when protection from by-pass contactor triggered;
    • prohibition the motor start when protection of limiting the number of starts triggered;
    • protection from incorrect command;
    • shutdown and prohibition the motor start when protection of the external automation errors triggered;
    • shutdown and prohibition the motor start at Mains voltage excess by preset setting;
    • shutdown the motor at Mains current excess by preset setting;
    • shutdown the motor when underload by the active component of current with the least current phase (the actual load). In this case setting is selected relatively the rated active current;
    • shutdown the motor at overload of any phase with a choice of maximum phase current at a regulated amp-second characteristic by separately selecting settings for current and overload time;
    • shutdown and prohibition the motor start at insulation resistance of "submersible cable - submersible motor" below a specified value;
    • prohibition the motor start at the turbine rotation of the pump unit;
    • shutdown the motor at a signal of exceeding any of 8 analog inputs;
    • prohibition the motor start at unauthorized door opening of UPPVE1 PN;
       

    .

    .

    UPPVE1 PN provides the following control functions:

    • start and stop the motor in "manual" or "automatic" mode;
    • operating by the program with a separate specified operating and stopping time intervals;
    • automatic motor start with the specified time delay after power-up or restoring power supply in accordance with the normal operating;
    • Adjustable trip delay separately for each protection (except protection against the low insulation resistance);
    • adjustable delay of activation protection immediately after start-up for each protection (except protection against the low insulation resistance);
    • adjustable delay of autoreclosure separately after each trip protection (except protection against the low insulation resistance and turbine rotation);
    • can choose a mode with automatic reclosure or automatic reclosure-locked after each trip separately protection (except protection against the low insulation resistance and turbine rotation);
    • choice to activate and deactivate protections separately for each protection;
    • blocking automatic reclosure after stopping by the protection against the underload at exceeding of the specified number of starts in specified time;
    • blocking automatic reclosure after stopping by the protection against the overload at exceeding of the specified number of restarts in specified time;
    • blocking automatic reclosure after stopping by other protections ( except protections against underload and overload) at exceeding of the specified number of restarts in specified time;
    • receipt and processing of the current value of the insulation of "submersible cable-submersible motors";
    • measurement of the current power consumption;
    • measurement of the current power factor (cos j);
    • calculation of the current value of the actual motor load;
    • measurement of the current value of the motor speed;
    • definition of phase sequence of the Mains (АВС or СВА);
    • display in chronological order last 99 changes in the state of the pumping unit with the reason and start and stop time of submersible motors; o record information to the memory block in real time about the causes of the motor start and stop with the registration of the current line value of power supply voltage, phase current of the motor, load, cosj, insulation, pressure, temperature, and the signals from the eight analog inputs. The recording is performing at the moment of the motor stop, 2 seconds after the start and during operation with two adjustable recording periods. If necessary to record parameters during the motor stop with two adjustable periods. In addition, memory stored the information about time and date of the settings change, old and new values, and the date and time of Mains switching on and off with the parameters registration right immediately after feeding and then with the adjustable period, if the voltages do not permit the switching on of the pumping unit. Stored information can be upload to the laptop.
    • storing the operating parameters and accumulated information while power supply is absent
    • LED indication status the station ("ALARM", "WAITING", "OPERATING");
       